myst:
html_meta:
product-name: Blackhole p150a, Blackhole p150b, Tenstorrent
technology-concepts: QSFP-DD, mesh, PCIe, cabling, topology
document-type: how-to
---
# Multi-Card Topologies
The Blackhole p150a and p150b each have four passive QSFP-DD 800G ports. Cabling those ports to other Blackhole cards builds a mesh in which the cards exchange data directly, without going through the host's PCIe bus. This page covers Tenstorrent-validated 2-, 4-, and 8-card configurations, recommended cables, and how to check the result.
:::{note}
The p100a has no card-to-card ports and cannot join a mesh.
:::
:::{important}
The QSFP-DD ports connect only to other Blackhole-based cards. They are not standard Ethernet ports and do not connect to switches or network adapters.
:::
## Validated Configurations
Do not treat every configuration as a fully populated mesh. A card has four ports, but the validated configurations use only as many as their topology needs.
| Cards | Card Type | Topology | External Cables |
| ----- | --------------- | ------------------------ | --------------- |
| 2 | p150a | 1×2 mesh | 1 |
| 4 | p150a or p150b | Ring of four (2×2 mesh) | 8 |
| 8 | p150b | 2×4 mesh | 10 |
:::{note}
The p150a and p150b are the Blackhole variants documented for multi-card operation. The p150a is intended for actively cooled desktop systems, and the p150b requires forced-air rack cooling. Mixing p150a and p150b cards in one mesh is not a documented configuration.
:::
If you would prefer a pre-built, validated desktop workstation powered by four Blackhole processors, please see the [TT-QuietBox 2](https://tenstorrent.com/hardware/tt-quietbox).
## Before You Cable
1. Confirm every card enumerates before you add cables. With the host powered on and no card-to-card cables connected, run `lspci -d 1e52:` and check that you see one entry per card. This separates any potential PCIe problems from cabling problems.
2. Power off the host before connecting or disconnecting cables. After cabling, power back on and confirm the cards still enumerate.
3. Check case or rack clearance. The connectors face out of the bracket. Leave room behind the slots to route cables without sharp bends. See [Choosing Host Hardware](host-hardware.md#rear-clearance-for-qsfp-dd-cabling) for more details on ensuring clearance for mesh cables.
4. Number the cards and ports using the convention below, and label your cables before routing them.
## Cables
For standard short-reach setups, use validated 0.5m passive QSFP-DD 800G cables, available from the [Tenstorrent store](https://tenstorrent.com/hardware/cards). If you need more reach, these 1 m passive QSFP-DD 800G cables are recommended: [Amphenol SF-NJYYEK0001-001M](https://cablesondemand.com/qsfp-dd-direct-attach-cables-200g-400g-800g-dac-1/amphenol-sf-njyyek0001-001m-1m-3-3-800g-qsfp-dd-112g-cable-800-gigabit-ethernet-passive-direct-attach-qsfp-double-density-112g-cable-dual-entry-32-awg-qsfp-dd-112g-to-qsfp-dd-112g-sf-njyyek0001-001m) or FS QDD-800G-PC01.
:::{important}
Use only passive QSFP-DD cables.
:::
## Port and Card Numbering
On p150a and p150b systems, Port 1 is the top connector, furthest from the motherboard, and Port 4 is the bottom connector, closest to the motherboard. In a rackmount system, number the cards from left to right, starting with Card 1 (or Tray 1).
```{image} ./images/bh_portspec.png
:width: 50%
```
*p150b pictured; the p150a has the same ports. Port 1 is the top connector.*
The diagrams on this page label cards C1, C2, and so on.
Each p150 card has one Blackhole chip, so a card-to-card link is also a chip-to-chip link. Each QSFP-DD cable carries two Ethernet links between the two cards it joins. The TT-Metalium software counts these links as *channels*, so one cable adds two channels between a pair of cards and two cables add four.
## Two Cards
### Supported Topology
Two p150a cards form a 1×2 mesh. TT-Metalium selects this topology automatically when it finds two p150 cards, using the `p150_x2` mesh graph descriptor, which expects four channels between the cards.
### Topology Description
The two cards connect directly to each other with a single QSFP-DD cable. One cable gives two Ethernet links between C1 and C2. There are no intermediate hops.
```text
+--------+ 1 QSFP-DD cable +--------+
| C1 |<----------------------> | C2 |
+--------+ (2 Ethernet links) +--------+
```
### Port Configuration
Number the cards C1 and C2 by PCIe slot, with C1 in the lower-numbered slot. Each card has four slots, and multiple 2-card configurations are valid. Connect one cable between the cards:
| Cable | From | To |
| ----- | ----------- | ----------- |
| 1 | Any port on C1 | Any port on C2 |
### Required Cables
You will need **one** passive QSFP-DD 800G cable. A 0.5 m cable is long enough for cards in adjacent slots. See [Cables](#cables).
If you wish, you can use more than one cable to connect two cards. This provides extra bandwidth, which can be helpful if you are moving significant data between cards.
### Other Possible Topologies
The following configurations can work but are not validated or tuned by Tenstorrent:
* **Two cables.** The mesh still forms and you get four Ethernet links instead of two, so card-to-card bandwidth is doubled.
* **Three or four cables (maximum).** Each card has four ports, so up to four cables can join the two cards. The software is configured for four channels between the cards, so it may not use the extra links, and Tenstorrent has not tested this configuration.
## Four Cards
### Supported Topology
The recommended four-card topology is a mesh of four cards, which TT-Metalium treats as a 2×2 mesh with the `p150_x4` mesh graph descriptor.
### Topology Description
Each card connects to three neighbors at least once, forming a closed mesh: C1–C2–C3–C4–C1 + C1-C3 + C2-C4. Every neighboring pair is joined by at least two cables, giving at least four Ethernet links per pair.
```text
C1 ==== C2
| \ / |
| / \ |
C4 ==== C3
```
*Each `====` or `||` is two cables.*
TT-Metalium maps the ring to a 2×2 mesh, so each card has one neighbor along each mesh axis.
### Required Cables
You will need **eight** passive QSFP-DD 800G cables. Eight cables use all 16 ports on four cards. Cables 1 through 6 join adjacent slots. Cables 7 and 8 must reach from C4 to C1, so measure that distance in your case and choose a length that reaches without tension. See [Cables](#cables).
### Other Possible Topologies
The following configurations can work but are not validated or tuned by Tenstorrent:
* **Four cables (minimum for a 2×2 mesh).** One cable between each neighboring pair (cables 1, 3, 5, and 7 above) still closes the ring and forms the 2×2 mesh. Each pair has two Ethernet links instead of four, so card-to-card bandwidth is halved. With fewer than four cables the ring is open, and the software may not detect a 2×2 mesh.
* **1×4 line.** Some models treat the four cards as a line (C1–C2–C3–C4) instead of a 2×2 mesh. They use the same eight-cable ring, so no recabling is needed. Cabling only the line, without cables 7 and 8, is not tested.
* **No maximum beyond eight.** The eight-cable ring already uses every port.
## Eight Cards
### Supported Topology
Eight p150b cards form a 2×4 mesh, using the `p150_x8` mesh graph descriptor.
An eight-card mesh requires p150b cards in a rack-mounted server with forced-air cooling. See {doc}`Choosing Host Hardware `.
### Topology Description
The cards form two rows of four. Cards 1–4 make one row and cards 5–8 make the other. Each card connects to the cards beside it in its row, and to the card in the same position in the other row. Each connection is one cable, giving two Ethernet links per neighboring pair.
```text
C1 ---- C2 ---- C3 ---- C4
| | | |
C5 ---- C6 ---- C7 ---- C8
```
There are no wraparound links. C1 and C4 are not connected, and the corner cards have only two neighbors.
### Port Configuration
Number the cards from left to right as seen from the rear of the server, C1 through C8. Connect ten cables:
| Cable | From | To | Connection |
| ----- | --------- | --------- | -------------- |
| 1 | C1 port 3 | C2 port 4 | Row 1 |
| 2 | C2 port 3 | C3 port 4 | Row 1 |
| 3 | C3 port 3 | C4 port 4 | Row 1 |
| 4 | C5 port 3 | C6 port 4 | Row 2 |
| 5 | C6 port 3 | C7 port 4 | Row 2 |
| 6 | C7 port 3 | C8 port 4 | Row 2 |
| 7 | C1 port 2 | C5 port 1 | Between rows |
| 8 | C2 port 2 | C6 port 1 | Between rows |
| 9 | C3 port 2 | C7 port 1 | Between rows |
| 10 | C4 port 2 | C8 port 1 | Between rows |
:::{figure} ./images/bh_8card_2x4_mesh.jpg
:width: 80%
:::
### Required Cables
You will need **ten** passive QSFP-DD 800G 0.5 m cables.
:::{note}
An eight-card system has 32 ports, but the validated configuration uses ten cables (20 ports), not every port. The twelve open ports are the ones used to connect servers to each other. Do not cable them inside a single server.
:::
### Other Possible Topologies
The following configurations can work but are not validated or tuned by Tenstorrent:
* **4 cables can be run between 2 cards for higher throughput.
* **Ten cables is the minimum for a 2×4 mesh.** Each neighboring pair has only one cable, so removing any cable leaves two neighbors with no direct link.
* **Extra single-server links.** The twelve open ports could add wraparound links (for example, C1 to C4) or a second cable between neighbors. TT-Metalium's `p150_x8` descriptor does not use these, and Tenstorrent cannot guarantee performance or error-free operation on topologies you create.
* **Multiple servers.** Two servers form a 4×4 mesh and four servers form an 8×4 mesh using the open ports. Multi-server scale-out is in development.
## Verify the Topology
For a single host, run the following command to ensure every card enumerates:
```bash
lspci -d 1e52:
```
You should see one `Tenstorrent Inc Blackhole` entry per Blackhole chip. A p100a, p150a or p150b has one chip, so you see one entry per card.
For multi-node or descriptor-backed topology validation, use [`run_cluster_validation`](https://docs.tenstorrent.com/cloud-native-support/hardware-validation.html) with the expected cabling and deployment descriptors. The tool can print physical connectivity, send traffic across the detected links, and report missing or unhealthy connections.
As a functional check, run a multi-card workload such as the Llama 3.1 8B demo in [TT-Transformers](https://github.com/tenstorrent/tt-metal/tree/main/models/tt_transformers).
## Troubleshooting
### A card is missing from `lspci`
This is a PCIe problem, not a cabling problem. See [FAQ and Troubleshooting](faq.md#my-card-is-not-enumerating).
### Cards enumerate but the multi-card demo fails or is slow
Power off, reseat each cable until it clicks, and compare your wiring with the diagram for your system. Two swapped cables can leave the mesh looking connected but routing incorrectly.
### A cable will not seat or is under tension
Case clearance is too small or the cable is too short. Do not force it. See [Choosing Host Hardware](host-hardware.md#rear-clearance-for-qsfp-dd-cabling).
## Related pages
* {doc}`Choosing Host Hardware `
* [TT-Topology](https://github.com/tenstorrent/tt-topology)
* {doc}`Blackhole PCIe Cards `