tt_ai_clock_mhz

<< Home | << Metrics

Name

Prometheus Metric Name

tt_ai_clock_mhz

Metric Path (tt-telemetry)

Schema:

{hostname}/tray{tray}/chip{chip}/tt_ai_clock_mhz

Example path:

bh-glx-c09u02/tray1/chip2/tt_ai_clock_mhz

Description

The AI clock frequency of the ASIC in megahertz (MHz). This is the operating frequency of the AI processing cores on the chip. The value is read from ARC firmware telemetry. When a workload is running on the chip, the clock speed will ramp up to the limit value (tt_ai_clock_limit_mhz). A clock speed at or near the limit is therefore indicative of an active workload. This metric is only created if the device reports AI clock data; not all device configurations expose it.

Values

Type: Unsigned Integer

Units: Megahertz (MHz)

Allowable values: A non-negative integer representing the clock frequency. For example, a value of 1200 means the AI clock is running at 1200 MHz (1.2 GHz).

Prometheus Labels

Label Name

Value

hostname

The host from which the metric was collected.

hall

The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD).

aisle

The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD).

rack

The rack number where the host is located. Sourced from the Factory System Descriptor (FSD).

shelf_u

The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD).

tray

The tray (UBB) that the device is located on.

chip

The ASIC location within the tray.

unit

The unit of measurement. Always "MHz" for this metric.