tt_arc_heartbeat
Name
Prometheus Metric Name
tt_arc_heartbeat
Metric Path (tt-telemetry)
Schema:
{hostname}/tray{tray}/chip{chip}/tt_arc_heartbeat
Example path:
bh-glx-c09u02/tray1/chip2/tt_arc_heartbeat
Description
Indicates whether the ARC processor heartbeat counter has changed since the last telemetry update. A value of true (1 in Prometheus) means the ARC firmware is running and responsive. A value of false (0) means the heartbeat counter did not change, which may indicate the ARC processor is hung or unresponsive. This metric is always available on all devices.
Values
Type: Boolean
Units: None
Allowable values:
true (1) — heartbeat changed since the last update (ARC is alive).
false (0) — heartbeat did not change since the last update (ARC may be unresponsive).
Prometheus Labels
Label Name |
Value |
|---|---|
hostname |
The host from which the metric was collected. |
hall |
The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD). |
aisle |
The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD). |
rack |
The rack number where the host is located. Sourced from the Factory System Descriptor (FSD). |
shelf_u |
The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD). |
tray |
The tray (UBB) that the device is located on. |
chip |
The ASIC location within the tray. |