tt_board_power_limit_w

<< Home | << Metrics

Name

Prometheus Metric Name

tt_board_power_limit_w

Metric Path (tt-telemetry)

Schema:

{hostname}/tray{tray}/chip{chip}/tt_board_power_limit_w

Example path:

bh-glx-c09u02/tray1/chip2/tt_board_power_limit_w

Description

The board power limit in watts. This is the maximum power the board is configured to draw. Compare with tt_tdp_w to monitor current power consumption relative to the board’s power limit. This metric is only available on devices whose firmware supports reporting the board power limit.

Values

Type: Unsigned Integer

Units: Watts

Allowable values: A non-negative integer representing the board power limit. For example, 300 means the board power limit is 300 watts.

Prometheus Labels

Label Name

Value

hostname

The host from which the metric was collected.

hall

The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD).

aisle

The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD).

rack

The rack number where the host is located. Sourced from the Factory System Descriptor (FSD).

shelf_u

The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD).

tray

The tray (UBB) that the device is located on.

chip

The ASIC location within the tray.

unit

The unit of measurement. Always "W" for this metric.