tt_ethernet_crc_error_count
Name
Prometheus Metric Name
tt_ethernet_crc_error_count
Metric Path (tt-telemetry)
Schema:
{hostname}/tray{tray}/chip{chip}/channel{channel}/tt_ethernet_crc_error_count
Example path:
wh-glx-c09u02/tray1/chip2/channel0/tt_ethernet_crc_error_count
Description
The number of CRC (Cyclic Redundancy Check) errors encountered on a specific Ethernet channel. CRC errors indicate data corruption during transmission. This metric is only available on Wormhole B0 devices and reads the CRC error count directly from device memory.
Values
Type: Unsigned Integer
Units: None
Allowable values: A non-negative integer representing the cumulative count of CRC errors.
Prometheus Labels
Label Name |
Value |
|---|---|
hostname |
The host from which the metric was collected. |
hall |
The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD). |
aisle |
The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD). |
rack |
The rack number where the host is located. Sourced from the Factory System Descriptor (FSD). |
shelf_u |
The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD). |
tray |
The tray (UBB) that the device is located on. |
chip |
The ASIC location within the tray. |
channel |
The Ethernet channel number on the chip. |
port_type |
The physical port type (e.g., QSFP, backplane). Present when topology information is available. |
port_id |
The physical port ID. Present when topology information is available. |
remote_hostname |
The hostname of the remote endpoint. Present when remote endpoint information is available. |
remote_tray |
The tray number of the remote endpoint. Present when remote endpoint information is available. |
remote_chip |
The ASIC location of the remote endpoint. Present when remote endpoint information is available. |
remote_channel |
The Ethernet channel of the remote endpoint. Present when remote endpoint information is available. |
remote_hall |
The datacenter hall of the remote endpoint. Present when remote endpoint information is available. |
remote_aisle |
The datacenter aisle of the remote endpoint. Present when remote endpoint information is available. |
remote_rack |
The rack number of the remote endpoint. Present when remote endpoint information is available. |
remote_shelf_u |
The shelf U position of the remote endpoint. Present when remote endpoint information is available. |