tt_ethernet_rxq_packet_drop_count

<< Home | << Metrics

Name

Prometheus Metric Name

tt_ethernet_rxq_packet_drop_count

Metric Path (tt-telemetry)

Schema:

{hostname}/tray{tray}/chip{chip}/channel{channel}/queue{queue}/tt_ethernet_rxq_packet_drop_count

Example path:

bh-glx-c09u02/tray1/chip2/channel0/queue0/tt_ethernet_rxq_packet_drop_count

Description

The cumulative number of dropped packets on a specific Ethernet receive (RX) queue. A drop occurs when an incoming packet cannot be accepted, for example because the queue is full. Each Ethernet channel exposes multiple RX queues, distinguished by the queue label.

This metric is only available on Blackhole devices. It is read as a single 64-bit value from boot_results.eth_live_status.rxq<queue>_pkt_drop.

Values

Type: Unsigned Integer

Units: None

Allowable values: A non-negative 64-bit integer representing the cumulative count of dropped packets on the queue.

Prometheus Labels

Label Name

Value

hostname

The host from which the metric was collected.

hall

The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD).

aisle

The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD).

rack

The rack number where the host is located. Sourced from the Factory System Descriptor (FSD).

shelf_u

The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD).

tray

The tray (UBB) that the device is located on.

chip

The ASIC location within the tray.

channel

The Ethernet channel number on the chip.

queue

The RX queue number on the Ethernet channel (0-2).

port_type

The physical port type (e.g., QSFP, backplane). Present when topology information is available.

port_id

The physical port ID. Present when topology information is available.

remote_hostname

The hostname of the remote endpoint. Present when remote endpoint information is available.

remote_tray

The tray number of the remote endpoint. Present when remote endpoint information is available.

remote_chip

The ASIC location of the remote endpoint. Present when remote endpoint information is available.

remote_channel

The Ethernet channel of the remote endpoint. Present when remote endpoint information is available.

remote_hall

The datacenter hall of the remote endpoint. Present when remote endpoint information is available.

remote_aisle

The datacenter aisle of the remote endpoint. Present when remote endpoint information is available.

remote_rack

The rack number of the remote endpoint. Present when remote endpoint information is available.

remote_shelf_u

The shelf U position of the remote endpoint. Present when remote endpoint information is available.