tt_fabric_rx_packets_total
Name
Prometheus Metric Name
tt_fabric_rx_packets_total
Metric Path (tt-telemetry)
Schema:
{hostname}/tray{tray}/chip{chip}/channel{channel}/fabric/tt_fabric_rx_packets_total
Example path:
bh-glx-c09u02/tray1/chip2/channel0/fabric/tt_fabric_rx_packets_total
Description
The total number of packets received on a specific fabric Ethernet channel. This is a cumulative counter from fabric telemetry. This metric is available on Wormhole B0 and Blackhole devices.
Note: Fabric metrics are only updated by fabric firmware when workloads are run with fabric telemetry explicitly enabled. For example, by setting the environment variable TT_METAL_FABRIC_TELEMETRY to 1.
Values
Type: Unsigned Integer
Units: None
Allowable values: A non-negative integer representing the total packets received. This is a monotonically increasing counter.
Prometheus Labels
Label Name |
Value |
|---|---|
hostname |
The host from which the metric was collected. |
hall |
The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD). |
aisle |
The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD). |
rack |
The rack number where the host is located. Sourced from the Factory System Descriptor (FSD). |
shelf_u |
The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD). |
tray |
The tray (UBB) that the device is located on. |
chip |
The ASIC location within the tray. |
channel |
The Ethernet channel number on the chip. |
port_type |
The physical port type (e.g., QSFP, backplane). Present when topology information is available. |
port_id |
The physical port ID. Present when topology information is available. |
remote_hostname |
The hostname of the remote endpoint. Present when remote endpoint information is available. |
remote_tray |
The tray number of the remote endpoint. Present when remote endpoint information is available. |
remote_chip |
The ASIC location of the remote endpoint. Present when remote endpoint information is available. |
remote_channel |
The Ethernet channel of the remote endpoint. Present when remote endpoint information is available. |
remote_hall |
The datacenter hall of the remote endpoint. Present when remote endpoint information is available. |
remote_aisle |
The datacenter aisle of the remote endpoint. Present when remote endpoint information is available. |
remote_rack |
The rack number of the remote endpoint. Present when remote endpoint information is available. |
remote_shelf_u |
The shelf U position of the remote endpoint. Present when remote endpoint information is available. |