tt_thermal_throttle_limit_celsius

<< Home | << Metrics

Name

Prometheus Metric Name

tt_thermal_throttle_limit_celsius

Metric Path (tt-telemetry)

Schema:

{hostname}/tray{tray}/chip{chip}/tt_thermal_throttle_limit_celsius

Example path:

bh-glx-c09u02/tray1/chip2/tt_thermal_throttle_limit_celsius

Description

The thermal throttle threshold in degrees Celsius. When the ASIC temperature reaches this limit, the device will begin thermal throttling to reduce power and temperature. Compare with tt_asic_temperature_celsius to monitor proximity to the throttle threshold. This metric is only available on devices whose firmware supports reporting the throttle limit.

Values

Type: Floating Point

Units: Degrees Celsius

Allowable values: A floating-point number representing the throttle temperature threshold. For example, 95.0 means the device will begin throttling at 95 degrees Celsius.

Prometheus Labels

Label Name

Value

hostname

The host from which the metric was collected.

hall

The datacenter hall where the host is located. Sourced from the Factory System Descriptor (FSD).

aisle

The datacenter aisle where the host is located. Sourced from the Factory System Descriptor (FSD).

rack

The rack number where the host is located. Sourced from the Factory System Descriptor (FSD).

shelf_u

The shelf U position in the rack where the host is located. Sourced from the Factory System Descriptor (FSD).

tray

The tray (UBB) that the device is located on.

chip

The ASIC location within the tray.

unit

The unit of measurement. Always "°C" for this metric.